Pressure Transducers
Vol. 17 #2, July 1990

Be sure to zero the transducer at operating temperatures since this will change with temperature due to thermal expansion.

Never handle, unscrew, or tighten a transducer with solidified polymer near the tip. You will tear the diaphragm.