Suction Pressure
Vol. 24 #2, Sept. 1997
When using an extrusion gear pump where pump suction pressure is higher than discharge, a regenerative drive system must be used to prevent the extruder from hydraulically drawing the pump and compromising the metering accuracy.
- Dan Smith, LCI Corp.