Transducer Accuracy
Vol. 22 #3, Dec. 1995

In spite of advances in pressure transducers, the reading is still a function of the torque used to install it and the operating temperature of the process.

For sensitive applications (+/ 5% of scale), calibrations should be performed at operating temperature and use a torque wrench to install.

See also:
  • Pressure transducers
  • Pressure transducers 2
  • Transducer calibration

Return to Extrusion Hints