SPE Extrusion Division 1-0-Wiki

RSS

Navigation

Extrusion 1-0-Wiki Pages

Search the Wiki
»

Viewing/Creating

Account Management

Administration

Brought to you by:
The SPE Extrusion Division
Board of Directors


PoweredBy
Pressure Transducers
Vol. 17 #2, July 1990

Be sure to zero the transducer at operating temperatures since this will change with temperature due to thermal expansion.

Never handle, unscrew, or tighten a transducer with solidified polymer near the tip. You will tear the diaphragm.

See also:
  • Calibrate transducers
  • Pressure blips
  • Pressure transducer handling
  • Pressure transducers 2
  • Transducer accuracy
  • Transducer removal
  • Transducer calibration

Return to Extrusion Hints
Some of the icons were created by FamFamFam.