SPE Extrusion Division 1-0-Wiki

RSS

Navigation

Extrusion 1-0-Wiki Pages

Search the Wiki
»

Viewing/Creating

Account Management

Administration

Brought to you by:
The SPE Extrusion Division
Board of Directors


PoweredBy
Tidal Waves Vol. 17 #2, July 1990

Strand cooling troughs have to be moved quickly on occasions, to work at the die or to adjust the distance to the die. Sudden acceleration of the bath on wheels causes surprisingly high waves and floodings that can even splash and freeze the die or extruder barrel.

Before moving the bath, 2 3 sheet metal plates can be inserted in vertical slots across the trough (4 feet apart). They break the waves and allow for quick moves of the trough without draining it.

During stranding operation, the plates will be stored (hanged) at the side of the trough.

See also:
  • Poor stranding
  • Strand cooling: good housekeeping

Return to Extrusion Hints
Some of the icons were created by FamFamFam.