Data Collection 1

Modified on Sunday, 01 February 2015 11:05 PM by mpieler — Categorized as: Extrusion Hints

Data Collection 1
Vol. 22 #2, Sept. 1995

During data entry on a modern data con trol system, the operator can lose sight of vital extruder parameters, e.g. melt pressure, motor load, and melt tempera ture, because the changes are made on different pages.

By providing separate display instruments for these values, the extrusion process can be checked quickly without scrolling through several pages on DCS screens.

See also:
Return to Extrusion Hints