Vent Design
Modified on Sunday, 01 February 2015 11:07 PM by mpieler — Categorized as: Extrusion Hints
Vent Design
Vol. 22 2, Sept. 1995
When scaling up vented extruders, be sure to allow for the increase in the vent vapor velocity and possible entrainment/fouling of the vent. Vent velocity will increase directly proportional to the ratio of the screw diameter scale up.
If the vent is running borderline on the smaller scale, it will be unacceptable on the larger scale. A guideline for safe vent operation is to have the vent vapor velocity less than 7 ft./sec.
See also:
Vent openings
Vent bleed
Vent flow
Vent insert design
Vent plugging
Vents 1
Vents 2
Return to
Extrusion Hints