Thermocouple Connections 2
Modified on Sunday, 01 February 2015 05:23 PM by mpieler — Categorized as: Extrusion Hints
Thermocouple Connections 2
Vol. 19 #1, Feb. 1992
A field expedient method for providing thermocouple connector strain relief is to overwrap the rear of the thermocouple connector with wire and then tape over the wire with glass (high temperature) tape.
Go back and forth over the union of wire and connector body 4 to 6 times, for best results.
See also:
Barrel thermocouple maintenance
Thermocouple connections 1
Thermocouples