Calibrate Transducers
Modified on Sunday, 01 February 2015 05:03 PM by mpieler — Categorized as: Extrusion Hints
Calibrate Transducers
Vol. 17 #3, Dec. 1990
Pressure readings from pressure transducers should be checked with a dead weight tester. Care must be taken not to damage the pressure foot during testing.
See also:
Pressure transducer handling